Surgical

Mednics, a leading US-based medical equipment company, manufactures high-quality medical devices. Committed to accessible healthcare, we offer surgical, ICU, imaging, and neonatal care equipment, ensuring reliability, innovation, and superior patient care for hospitals, clinics, and research facilities.

Anaesthesia System KAM-A100

  • Drive: Electronically controlled, pneumatic drivenElectronically controlled, pneumatic driven
  • Tidal Volume: 0 ml -1500 ml0 ml -1500 ml
  • Configuration: Trolley / Table-top ventilationTrolley / Table-top ventilation
  • Gas Configuration: O2, N2OO2, N2O

Anaesthesia System KAM-A101

  • Drive: Electronically controlled, bellow drivenElectronically controlled, bellow driven
  • Tidal Volume: 0 ml – 1500 ml0 ml – 1500 ml
  • Gas Configuration: O2, N2OO2, N2O
  • Flow Meter: 1 l/min – 10 l/min1 l/min – 10 l/min
Anaesthesia System KAM-A102
  • Drive: Electronically controlled, pneumatic drivenElectronically controlled, pneumatic driven
  • Tidal Volume: 20 ml – 1500 ml20 ml – 1500 ml
  • Gas Configuration: O2, N2OO2, N2O
  • Flow Meter: Cascade, 0 L/min -10 L/minCascade, 0 L/min -10 L/min
Anaesthesia System KAM-A200
  • Drive: Electronically controlled, pneumatic drivenElectronically controlled, pneumatic driven
  • Tidal Volume: 0 ml ~ 1500 ml0 ml ~ 1500 ml
  • Ventilation Modes: A/C, IPPV, SIPPV, ManualA/C, IPPV, SIPPV, Manual
  • Gas Configuration: O2, N2OO2, N2O

Anaesthesia System KAM-B100

  • Ventilation Modes: IPPV, PCV, SIMV + PS, PS and ManualIPPV, PCV, SIMV + PS, PS and Manual
  • Tidal Volume: 20 ml to 1500 ml20 ml to 1500 ml
  • Pressure (Inspiratory): 5 cmH2O – 70 cmH2O5 cmH2O – 70 cmH2O
  • Pressure (Support): 3 cmH2O – 50 cmH2O3 cmH2O – 50 cmH2O

Mobile C-Arm X-ray KCX-A100

  • X-Ray Generator: Frequency 40 kHz
    Power Capacity 3.5 kWFrequency 40 kHz
    Power Capacity 3.5 kW
  • Tube Current: X-ray : 20 mA - 63 mA
    Fluoroscopy : 8 mAX-ray : 20 mA - 63 mA
    Fluoroscopy : 8 mA
  • Tube Voltage: 40 kV ~ 110 kV40 kV ~ 110 kV
  • Exposure Factor: 1 ~ 125 mAs1 ~ 125 mAs
Surgical Diathermy Machine KSD-A100
  • Power Consumption: 350 W350 W
  • Operating Frequency: 330 kHz ─ 460 kHz330 kHz ─ 460 kHz
  • Modes: 6 Monopolar modes
    2 Bipolar modes6 Monopolar modes
    2 Bipolar modes
  • Monopolar Cut : Pure Cut: 1 W ─ 350 W at 500 Ω load impedance1 W ─ 350 W at 500 Ω load impedance
Surgical Diathermy Machine KSD-B100
  • Power Consumption: 300 W300 W
  • Operating Frequency: 416 kHz416 kHz
  • Modes: 5 Monopolar modes
    2 Bipolar modes5 Monopolar modes
    2 Bipolar modes
  • Monopolar Cut : Pure Cut: 1 W ─ 300 W at 800 Ω load impedance1 W ─ 300 W at 800 Ω load impedance